FIACHECK TULIP POCT Fluorescence Immunoassay
Point-of-care fluorescence immunoassay system for rapid diagnostic testing.
Immunoassay & ELISA systems
Point-of-care fluorescence immunoassay system for rapid diagnostic testing.
Trusted immunoassay analyzer for high-volume testing.
Automated ELISA processing for consistent immunoassay results.
Immunoassay is where laboratories in this region most often buy capacity they do not yet have the volume to use, and then find the reagents expiring faster than the panel grows.
The sensible order is usually the reverse of the one people take. Start from the tests clinicians actually order — thyroid, fertility, cardiac markers, infectious serology — then work out how many of each per week, then pick the platform. A microplate ELISA setup built from the Bio-Rad PR 4100 reader and PW40 washer is cheap to own and runs in batches, which suits a laboratory that can hold samples until Thursday. It does not suit an emergency department waiting on a troponin.
Where results are needed singly and quickly, a random-access analyser earns its place: the Beckman Access 2 or the Mindray CL-1200i for a hospital laboratory, or fluorescence immunoassay like the Tulip FIACHECK and Boditech ichroma II where the footprint and the sample count are both small. The Bio-Rad Evolis Twin Plus sits between the two, automating the plate workflow for labs with real batch volume. The Athenese-Dx ADX-150 reader and ADX-140 washer are the economical route into plate work.
A plate holds 96 wells. Run twelve samples on it and you have paid for 96. That arithmetic, more than any specification, decides whether plate-based immunoassay suits you — and it is why a laboratory running eight TSH requests a day is usually better served by a cartridge system even though the cost per test looks higher on paper.
Immunoassay drifts quietly. Unlike a chemistry analyser throwing an obvious error, a slowly shifting immunoassay produces results that look entirely plausible and are wrong. Third-party controls — the Bio-Rad immunoassay QC material is the common choice — cost a little and are the only way you find out before a clinician does. NABL assessors look specifically at whether the controls are independent of the reagent manufacturer.
Cold chain matters for the kits as much as the instruments. If your reagent fridge is also the one holding somebody's lunch, fix that before buying anything on this page.
Installation, training and service from Patna, across Bihar and Jharkhand.
Tell us your daily sample count and we will tell you honestly what suits it — including when a cheaper option is the right one.