Blood Banks
Storage, incubators & centrifuges
12 models listed
Remi Platelet Rotator PR-10 Ultra
Gentle continuous agitation for platelet concentrate storage.
Remi PDV-185 Ultra Low Deep Freezer
Ultra-low temperature freezer for long-term blood component storage.
Remi KBM-80 Plus Blood Bank Centrifuge
LCD-controlled centrifuge purpose-built for blood bank workflows.
Bio-Rad PW40 Microplate Washer
Automated microplate washer for consistent assay preparation.
PR 4100 Absorbance Microplate Reader
Precise absorbance reading for microplate-based assays.
Blood bank equipment is bought against a licence inspection more often than against a workload, which changes what matters. The inspector will ask what temperature your platelets were held at last Tuesday, and whether you can show it. An instrument with no usable record is a problem whatever its specification.
The core of the room does not vary much: a refrigerated centrifuge rated for blood bags, a platelet incubator with an agitator, a deep freezer for plasma, and a reliable way of doing grouping and crossmatching. The Remi KBM-80 Plus covers bag separation, the PI 10 incubator and PR-10 Ultra rotator handle platelets, and the PDV-185 takes plasma down to storage temperature.
For immunohaematology the gel-card route — the Bio-Rad ID-Incubator L and ID-Centrifuge L, with the ID Centrifuge 12 S II — has largely replaced tube technique in licensed facilities here, mostly because the reaction stays readable long enough for a second person to check it and for the result to be photographed. That matters more than it sounds when a discrepancy has to be defended weeks later.
Power, again
Everything in this list is temperature-critical, and Bihar's supply is not. A deep freezer that loses power for four hours in May is a different problem from one that loses it in January. Generator backup for the blood bank room is not optional, and the alarm needs to reach somebody at night rather than simply sounding in an empty corridor. We have seen more product lost to an unheard alarm than to equipment failure.
Collection-side, the Blood Collection Monitor BCM 10 mixes and weighs during draw, which removes the two commonest causes of a unit being discarded: under-filling and clotting from poor mixing. For camps, where the bench is a folding table and the staff are borrowed, that is worth more than in the main unit.
Documentation
If you are preparing for a licence renewal or a tender, ask us for the calibration certificates and the temperature-mapping records at the point of purchase rather than afterwards. We would rather assemble that file with you than have you chase it a week before the inspection.
Supplied, installed and serviced across Bihar and Jharkhand.
Not sure which model fits your workload?
Tell us your daily sample count and we will tell you honestly what suits it — including when a cheaper option is the right one.